ELNet LTP

Energy analyzer with the measurement of the measurement of leakage currents


The widespread use of measurements of the electrical currents in the last few years has greatly accelerated the development of the measurement procedures.

The company Control Applications Ltd . sets in the field of electrical measurements high standards  with highprecision scales 1,600 measurements per period. This makes it possible to develop new models of Multimeters in that can additionally to all standard electrical measurements (voltage , current, power factor, frequency , power consumption ... ) also measure leakage currents . The new model Elnet LTP has with its performance and accuracy almost no competition. The model has the best features as well as a color display, a graphical user interface and built-in web server for remote control.


As an extra, the Elnet LTP has also:

- Two digital inputs which can accept the impulses of the other meters (water, gas , etc..) . The data can then be transmitted to SCADA, BMS.

Measurement of leakage currents is the best way to test the safety of electrical equipment. Electrical appliances or systems in which the leakage current is higher than the prescribed should be checked with a special test.

The Powermeter Elnet LTP is installed on the door of the switch block. The Powermeter measures permanently in addition to all other measurements also leakage currents. That is an additional measure of safety in the use of electrical equipment (eg. in medicine ). These measurements allow a relatively easy way to find the leak currents. The leakage currents are shown on the display. With stepwise switching off of the electric lines, the user can easily locate faults.


The device enables setting the maximum values of leakage currents. When the leakage currents exceed  this value, an alarm can be triggered, or a relay output can switch off an line.  The alarms can also be routed to a SCADA or BMS . From there they can be forwarded by SMS or email.


You can read more about leakage currents on the link http://elnet.feniks-pro.com/Leakage-currents.php page

In addition : measurement of leakage currents (in addition a fourth current transformer on neutral liner) - option can be turned off in the menu.
 

General

Simple operated menus.
  • Multilingual support.
  • Up to One year of energy data logging.
  • Displays up to 64th Harmonic in Waveform or Graphic.
  • 1600 samples per cycle.
  • Accuracy 0.2 %.
  • Accuracy 0.1% with special calibration, that can be ordered.
  • Build in T.O.U. Energy meter.
  • In addition : measurement of leakage currents (in addition a fourth current transformer on neutral liner) - option can be turned off in the menu.
  • RS485 Communication Port (MODBUS, Bacnet MS/TP).
  • State of the art Graphic LCD
  • Modern 320 x 240 LCD display.
  • Displays of Waveform and Bar graph.
  • Simple installation- Panel mounted. Dimension: 96x96 mm. 
  • Flash memory stores 6 months of energy.
  • Option: TCP/IP communication port + WEB server
  • BacNet TCP/IP

 
 
For more details and manuals please check Download section
 
 
 


 
 
 
You are examining the old version of our Elnet WEB page.
 
The data here is outdated.
 
For the best user experience please visits our new Elnet Online Shop at:
 
 
We offer to our loyal customers that are redirected from this page an -9% cart total off.
 
You can use coupon code:
 
oldElnetpage
 
The code is valid till 1.6.2016